SG Series

The SG Series is one of the best-performing, most reliable, and versatile three-phase UPS systems available for those who require critical power protection. It guarantees peace of mind regarding power for a wide range of applications with a low total cost of ownership (TCO).

This true online double-conversion UPS leverages network integration software and communication connectivity to provide comprehensive, easy-to-integrate power protection for almost any IT environment. The SG Series operates in VFI (voltage and frequency independent) mode, always maximizing load protection. The UPS runs an innovative control algorithm on the IGBT rectifier instead of standard filters to ensure the most efficient delivery of clean power.

The SG Series UPS provides first-class reliability and performance while complying with all relevant EMC and safety standards. ABB's unique RPA™ technology (redundant parallel architecture) allows units to operate in parallel, further increasing reliability and uptime.
  • Features
  • Parameters
  • Documents
  • Get a Quote
  • Provides maximum load protection at all times with true online double-conversion (VFI) operating mode
  • Offers high operating efficiency of up to 99% thanks to eBoost technology
  • Keeps input current harmonic distortion (THDI) below 2% with PurePulse IGBT rectifier
  • Allows parallel operation of up to 6 units without a single point of failure with Redundant Parallel Architecture (RPA) technology
  • Offers easy installation, operation, and maintenance advantages thanks to its full front access design
  • Output power factor is 1.0 for 10-40 kVA models and 0.9 for 60-600 kVA models
  • Provides superior short-circuit capacity and load isolation with an inverter zig-zag isolation transformer
  • Maximizes battery life and reliability with the Superior Battery Management (SBM) system
  • Features built-in maintenance bypass and backfeed protection
  • Prevents unnecessary battery discharge thanks to a wide AC input voltage and frequency range
  • Prevents sudden loads on the input power system with a programmable soft start feature
  • Offers a multilingual graphical LCD display and various communication ports (RS232, SNMP, etc.) for critical applications
General Data 10–40 kVA 60–80 kVA 100–120 kVA 160 kVA 200–300 kVA 400–500 kVA
System Power Range 10–40 kVA 60–80 kVA 100–120 kVA 160 kVA 200–300 kVA 400–500 kVA
Active Power / Cabinet 10/15/20/30/40 kW 54 / 72 kW 90 / 108 kW 144 kW 180 / 225 / 270 kW 360 / 450 kW
Output Power Factor 0.9 lead – 0.6 lag
Topology Online double conversion
UPS Type Standalone, transformer-based
Parallel Configuration Up to 6 units in parallel (Redundant Parallel Architecture – RPA)
INPUT
Nominal Input Voltage 3 × 380 / 400 / 415 V + N
Voltage Tolerance 340–460 V
Input Harmonic Distortion (THDi) <3%
Frequency 50 / 60 Hz
Frequency Range 45–66 Hz
Power Factor >0.99
Soft Start Yes
OUTPUT
Nominal Output Voltage 3 × 380 / 400 / 415 V + N
Voltage Tolerance ±1% static, ±3% dynamic, ±3% unbalanced load
Voltage Distortion (THDU) <2% linear load, <3% non-linear load (EN 62040)
Frequency 50 / 60 Hz
Overload Capacity 150%: 1 min, 125%: 10 min
Short Circuit Withstand 2.7 × In (phase-neutral) / 4 × In (phase-phase) 200 ms
Crest Factor <3:1
EFFICIENCY
Overall Efficiency Up to 92.3% Up to 91.9% Up to 92.1% Up to 94.2% Up to 94.6% Up to 94.2%
Eco Mode Up to 98% Up to 97.9% Up to 97.9% Up to 98.4% Up to 98.5% Up to 98.7%
ENVIRONMENT
Storage Temperature UPS: -25°C ~ +55°C
Operating Temperature 0°C ~ 40°C
Humidity Max. 95% (non-condensing)
Altitude No derating up to 1000 m;
1500 m: -2.5% / 2000 m: -5% / 2500 m: -7.5% / 3000 m: -10%
COMMUNICATION
HMI Multilingual graphical display (LCD)
Relay Contacts 6 potential-free contacts or 27 programmable alarms
Input Signals EPO, generator ON (generator power supply), 1 auxiliary signal
Communication Ports RS232, SNMP (Modbus), RS232, RS485 & BacNet IP
ELECTRICAL / MECHANICAL
Protection Class IP20
Color 10–120 kVA: RAL 9003 (white), 160–500 kVA: RAL 9005 (black)
Cable Entry Bottom (top optional)
Back-feed Protection Standard
Service Access Full front access
Cooling Front-to-back airflow
Sound Level <65 dB(A) 63 dB(A) 69 dB(A) 69 dB(A) 69 dB(A) 69 dB(A)
BATTERY
Battery Type VRLA, open-type lead-acid, NiCd, flywheel
DC Float Voltage 409–436 V
STANDARDS
Safety IEC / EN 62040-1
EMC IEC / EN 62040-2
Performance IEC / EN 62040-3
Certification CE mark
Manufacturing ISO 9001
WEIGHT & DIMENSIONS
Weight (kg) 290–420 550–630 860 1050 1220–1560 2190–2470
Dimensions (WxHxD mm) 680×1450×800 650×1900×850 835×1900×850 900×1900×850 1300×1900×850 1800×1900×950