tCON Series

The tCON series Static Voltage Regulator is one of the methods that provides a solution to the problematic nature of grid voltage.

tCON series static regulators do not contain mechanical parts. For this reason, wear problems are not encountered, and the product has a longer lifespan.

The control board continuously monitors the input and output voltage and current and makes corrections. Since it is a technologically newer product and performs its corrections digitally, it makes much faster and more accurate corrections compared to servo regulators. The regulation speed is 10 times that of servo regulators.

Static Regulators are also much more economical due to their technology, energy consumption, and operating principle.
  • Features
  • Parameters
  • Documents
  • Get a Quote
  • Fast and precise voltage control with static voltage regulation
  • Wide power range from 1kVA – 2000kVA
  • Single-phase and three-phase operation options
  • ±3% output tolerance (optional ±2%)
  • High regulation speed (~500 V/s)
  • High efficiency between 92% – 94%
  • 0.8 power factor
  • 50-60Hz operating frequency
  • Detailed monitoring with 4×16 character LCD screen
  • Input/output voltage, load, and frequency measurement
  • Alarm system for overload, over-temperature, and input/output faults
  • RS232 and dry contact standard communication
  • RS485, TCP/IP, SNMP, and GSM optional communication support
  • Current protection with thermal magnetic circuit breaker
  • Automatic cut-off protection when output voltage goes out of tolerance
  • Maintenance bypass line (15kVA and above)
  • Phase protection that stops the system in case of a phase fault (optional)
  • Input protection with RFI and harmonic filter (optional)
  • Isolation transformer for input and output (optional)
  • 20 years design life
  • IP20 – IP54 protection class (optional)
  • Fan-cooled (standard) or natural cooling (optional)
  • -10°C / +50°C operating temperature
  • Operation in 0% – 95% humidity range (non-condensing)
  • Operation with derating at altitudes above 1000m (max. 4000m)
  • Low noise level (<40 - 65 dB)
  • Robust and compact structure suitable for industrial use
KEY FEATURES
Power 1kVA – 200kVA 10kVA – 2000kVA
Input Phase Single Phase Three Phase
INPUT PARAMETERS
Input Voltage 120 / 127 VAC (Single Phase + N) 3×208 / 3×220 VAC (Three Phase + N)
Input Voltage Tolerance 95≤120≤145; 100≤127≤152 166≤208≤250; 176≤220≤264
Frequency 50 – 60 Hz ± 5%
OUTPUT PARAMETERS
Output Voltage 120 / 127 VAC (Single Phase + N) 3×208 / 3×220 VAC (Three Phase + N)
Output Tolerance ± 3% (Optional ± 2%)
Overload 115%: 10 min
125%: 1 min
150%: 10 sec
Above 150%: output cut-off
Output Frequency 50 – 60 Hz ± 5%
Regulation Speed ~500 V/s
Power Factor 0.8
Efficiency 92% 94%
Connection Appropriate terminal structure with 4×16 character LCD screen
Measurements Input power, input voltage, output voltage, load, frequency
Alarms Overload, over-temperature, input/output faults
Communication RS232 (Standard), Dry contact (Standard), RS485 (Optional)
TCP/IP, SNMP, GSM (Optional)
PROTECTION
Output Voltage Protection Cuts off output in case of out-of-tolerance voltage
Current Protection Thermal magnetic circuit breaker
Maintenance Maintenance bypass line (15kVA and above)
OPTIONS
Phase Protection Stops the system in case of a phase fault
RFI / Harmonic Filter Prevents fluctuations and surges at the input
Harmonic Filter Reduces high-frequency noise and harmonics
Isolation Transformer Input/output isolation for special applications
SYSTEM SPECIFICATIONS
Design Life 20 years
Protection Class IP20 (Standard) – IP54 (Optional)
Storage Temperature -20°C / +70°C
Operating Temperature -10°C / +50°C
Cooling Fan-cooled (Standard), natural (Optional)
Altitude 1000m (derating after 1000m, max 4000m)
Humidity 0% – 95% (non-condensing)
Noise <40 - 65 dB
Color RAL7035, RAL7032 (Other colors optional)
Cable Entry Bottom (Top entry optional)
STANDARDS
Standards ISO9001, ISO14001

No documents found for this product.

Please enable JavaScript in your browser to complete this form.