Inverta Series
Inverta Series
An inverter is a device or circuit system that converts direct current (DC) to alternating current (AC). This power converter, which can be defined as an electrical power conversion element, is utilized in a wide range of applications, from small power supplies in computers to large systems providing power to electrical distribution networks. Given current needs and technological advancements, it is evident that inverters have become a necessity due to their increasingly widespread application areas.
- Features
- Parameters
- Documents
- Get a Quote
- Seamless bypass transfer
- Fast processing (DSP control)
- High overload capacity
- IP20 – IP55 protection rating
- Audible and LED alarm system
- Modbus communication support
- TMS protection on all terminals
- Automatic startup and fault recovery
- Self-diagnosis and log recording system
- Smart charging and internal battery monitoring
- Easy maintenance with modular card structure
- Wide input range (±30%)
- Does not require an additional voltage regulator
- IGBT technology
- Output isolation transformer
| KEY FEATURES | ||
|---|---|---|
| Model | INVERTA-1 | INVERTA-3 |
| Output Phase | Single Phase | Three Phase |
| Conversion Topology | Insulated Gate Bipolar Transistor (IGBT Based) | |
| Control | DSP Controller | |
| INPUT PARAMETERS | ||
| Input Voltage | 24VDC – 220VDC (±20%) | 24VDC – 650VDC (±20%) |
| Bypass Voltage | 110VAC – 600VAC | |
| Bypass Frequency | 50Hz, 60Hz or 400Hz | |
| OUTPUT PARAMETERS | ||
| Output Power | Up to 200kVA | Up to 600kVA |
| Output Voltage | 110VAC – 600VAC | |
| Voltage Tolerance | ±1% (Static), ±5% (Dynamic 100% load change 50ms) | |
| Output Frequency | 50Hz, 60Hz or 400Hz (±1% synchronous, ±0.5 non-synchronous) | |
| Power Factor | 0.8 | |
| Efficiency | Up to 93% | |
| Waveform | Pure Sine Wave | |
| Transfer to Bypass | <5ms | |
| Transfer to Inverter | 0ms (Return delay adjustable) | |
| Crest Factor | 3:1 | |
| Overload (INV) | 125% Load: 10 min 150% Load: 1 min 200% Load: 1 sec |
|
| Overload (BYP) | 110% Load: Continuous 150% Load: 1 min 1000% Load: 50 ms |
|
| THD | <2% (linear), <5% (non-linear) | |
| PHYSICAL CHARACTERISTICS | ||
| Cabinet Type | Rack / Tower (Optional: Others) | |
| Cabinet Color | RAL7032, RAL7035 (Optional: Others) | |
| Protection Class | IP20 (Optional: IP21 – IP55) | |
| Cooling System | Fan cooling (Optional: Natural, water cooling, smart fan) | |
| Cable Entry | Bottom (Optional: Top, rear, side) | |
| ENVIRONMENTAL CONDITIONS | ||
| Storage Temperature | -25°C / +70°C | |
| Operating Temperature | -10°C / +50°C | |
| Humidity | 0% – 95% (Non-condensing) | |
| Operating Altitude | 1000m (1% derating for every 100m above 1000m) | |
| Noise Level | 55dB – 80dB | |
| COMMUNICATION | ||
| Standard Communication | ModBus RTU (RS232) (Optional: RS485, ModBus TCP/IP, SNMP, IEC61850), 4 dry contacts (Optional: Up to 16) | |
| Parallel Operation | Passive: Unlimited (Optional: Active: Up to 2 units) | |
| HMI | LED/LCD Panel (Optional: Touch screen, Mimic panel) | |
| Languages | Turkish, English, German, Dutch, Portuguese, Spanish, Russian | |
| PROTECTIONS | ||
| Input / Output Protection | MCB or MCCB for input and output | |
| Line fault, AC synchronization, short circuit | ||
| Current limiting, overload, overvoltage, undervoltage, overtemperature | ||
| ADDITIONAL FEATURES (OPT.) | ||
| MBS | Full isolation with maintenance bypass | |
| Parallel Operation | 1+1 system (Standby, load sharing, parallel redundant) | |
| Measurements | Input/Output voltage, current and frequency | |
| DC Power | Battery and output monitoring when AC is cut off | |
| Protection | Fan fault, fuse fault, breaker open, parallel fault | |
| Other | Cabinet heater, lighting, service outlet | |
| STANDARDS | ||
| EN62040-1 | General and safety requirements for UPS | |
| EN62040-2 | Electromagnetic compatibility (EMC) for UPS | |
| ISO14001 – ISO9001 | Quality management | |