Inverta Series

An inverter is a device or circuit system that converts direct current (DC) to alternating current (AC). This power converter, which can be defined as an electrical power conversion element, is utilized in a wide range of applications, from small power supplies in computers to large systems providing power to electrical distribution networks. Given current needs and technological advancements, it is evident that inverters have become a necessity due to their increasingly widespread application areas.
  • Features
  • Parameters
  • Documents
  • Get a Quote
  • Seamless bypass transfer
  • Fast processing (DSP control)
  • High overload capacity
  • IP20 – IP55 protection rating
  • Audible and LED alarm system
  • Modbus communication support
  • TMS protection on all terminals
  • Automatic startup and fault recovery
  • Self-diagnosis and log recording system
  • Smart charging and internal battery monitoring
  • Easy maintenance with modular card structure
  • Wide input range (±30%)
  • Does not require an additional voltage regulator
  • IGBT technology
  • Output isolation transformer
KEY FEATURES
Model INVERTA-1 INVERTA-3
Output Phase Single Phase Three Phase
Conversion Topology Insulated Gate Bipolar Transistor (IGBT Based)
Control DSP Controller
INPUT PARAMETERS
Input Voltage 24VDC – 220VDC (±20%) 24VDC – 650VDC (±20%)
Bypass Voltage 110VAC – 600VAC
Bypass Frequency 50Hz, 60Hz or 400Hz
OUTPUT PARAMETERS
Output Power Up to 200kVA Up to 600kVA
Output Voltage 110VAC – 600VAC
Voltage Tolerance ±1% (Static), ±5% (Dynamic 100% load change 50ms)
Output Frequency 50Hz, 60Hz or 400Hz (±1% synchronous, ±0.5 non-synchronous)
Power Factor 0.8
Efficiency Up to 93%
Waveform Pure Sine Wave
Transfer to Bypass <5ms
Transfer to Inverter 0ms (Return delay adjustable)
Crest Factor 3:1
Overload (INV) 125% Load: 10 min
150% Load: 1 min
200% Load: 1 sec
Overload (BYP) 110% Load: Continuous
150% Load: 1 min
1000% Load: 50 ms
THD <2% (linear), <5% (non-linear)
PHYSICAL CHARACTERISTICS
Cabinet Type Rack / Tower (Optional: Others)
Cabinet Color RAL7032, RAL7035 (Optional: Others)
Protection Class IP20 (Optional: IP21 – IP55)
Cooling System Fan cooling (Optional: Natural, water cooling, smart fan)
Cable Entry Bottom (Optional: Top, rear, side)
ENVIRONMENTAL CONDITIONS
Storage Temperature -25°C / +70°C
Operating Temperature -10°C / +50°C
Humidity 0% – 95% (Non-condensing)
Operating Altitude 1000m (1% derating for every 100m above 1000m)
Noise Level 55dB – 80dB
COMMUNICATION
Standard Communication ModBus RTU (RS232) (Optional: RS485, ModBus TCP/IP, SNMP, IEC61850), 4 dry contacts (Optional: Up to 16)
Parallel Operation Passive: Unlimited (Optional: Active: Up to 2 units)
HMI LED/LCD Panel (Optional: Touch screen, Mimic panel)
Languages Turkish, English, German, Dutch, Portuguese, Spanish, Russian
PROTECTIONS
Input / Output Protection MCB or MCCB for input and output
Line fault, AC synchronization, short circuit
Current limiting, overload, overvoltage, undervoltage, overtemperature
ADDITIONAL FEATURES (OPT.)
MBS Full isolation with maintenance bypass
Parallel Operation 1+1 system (Standby, load sharing, parallel redundant)
Measurements Input/Output voltage, current and frequency
DC Power Battery and output monitoring when AC is cut off
Protection Fan fault, fuse fault, breaker open, parallel fault
Other Cabinet heater, lighting, service outlet
STANDARDS
EN62040-1 General and safety requirements for UPS
EN62040-2 Electromagnetic compatibility (EMC) for UPS
ISO14001 – ISO9001 Quality management