FC Series
FC Series
This is an electrical power supply system for devices and equipment that operate on AC voltage but require a different frequency than the mains supply. Frequency converters are devices used to convert the 50Hz mains frequency to the 400Hz or 60Hz frequency required for the device's operation. Static frequency converters perform frequency conversion in two stages. First, the input voltage is converted to DC voltage with the help of rectifiers. Then, with the help of an inverter, this DC voltage is converted to AC voltage at the desired frequency, providing output at the desired voltage and frequency.
- Features
- Parameters
- Documents
- Get a Quote
- High reliability for marine environments (marine certified design)
- Compliance with Bureau Veritas, ABS, and DNV GL certifications
- 100% reliable operation in harsh marine and industrial conditions
- 400Hz operation support for airport and marine applications
- Clean and stable energy output
- Compliance with MILSPEC standards (for military applications)
- Durable and robust cabinet structure
- 28VDC auxiliary output support for aircraft testing
- Flexible frequency conversion structure suitable for various applications
- Uninterrupted and reliable energy solution for industrial and critical loads
| KEY FEATURES | |||
|---|---|---|---|
| Model | FC 3/3 | FC 3/1 | FC 1/1 |
| Input Phase | Three Phase | Three Phase | Single Phase |
| Output Phase | Three Phase | Single Phase | Single Phase |
| Nominal Power | Up to 600kVA | ||
| INPUT PARAMETERS | |||
| Input Voltage | 3x380VAC ±15% (190VAC – 460VAC optional) | 220VAC ±15% (110VAC – 260VAC optional) | |
| Frequency | 50Hz, 60Hz or 400Hz (±10%) | ||
| Phase Sequence | Automatic phase lock | ||
| Starting Current | 10 x Inom | ||
| OUTPUT PARAMETERS | |||
| Output Voltage | 3x380VAC ±15% (190VAC – 460VAC optional) | 220VAC ±15% (110VAC – 260VAC optional) | |
| Frequency | 50Hz, 60Hz or 400Hz (±10%) | ||
| Voltage Regulation | <1% | ||
| Voltage Recovery | <50ms (under unbalanced load) | ||
| Voltage Stability | <1% (balanced), <3% (unbalanced) | ||
| THDu | <2% | ||
| Overload Capacity | 110%: Continuous 125%: 1 hour 150%: 5 min 200%: 20 sec |
||
| Isolation | 1500 / 2000 / 3000VAC (Input & Output – Chassis) | ||
| PHYSICAL CHARACTERISTICS | |||
| Cabinet Type | Upright type (Optional: others) | ||
| Cabinet Color | RAL7032, RAL7035 (Optional) | ||
| Protection Class | IP20 (Optional: IP21 – IP55) | ||
| Cooling | Fan-cooled (Optional: natural, water, smart fan) | ||
| Cable Entry | Bottom (Optional: top, rear, side) | ||
| ENVIRONMENTAL CONDITIONS | |||
| Storage Temperature | -25°C / +70°C | ||
| Operating Temperature | -10°C / +50°C | ||
| Humidity | 0% – 95% (non-condensing) | ||
| Altitude | 1000m (1% derating thereafter) | ||
| Noise | 55dB – 80dB | ||
| COMMUNICATION | |||
| Standard Communication | ModBus RTU (RS232) (Optional: RS485, TCP/IP, SNMP, IEC61850) | ||
| Parallel Operation | Passive: unlimited (Optional: 2 devices) | ||
| HMI | LED/LCD panel (Optional: touchscreen) | ||
| Languages | Turkish, English, German, Dutch, Portuguese, Spanish, Russian | ||
| PROTECTIONS | |||
| Input / Output | MCB or MCCB | ||
| Mains failure (AC input) | |||
| Current limiting, DC ground fault, over temperature | |||
| Charge failure, emergency stop | |||
| ADDITIONAL FEATURES (OPT.) | |||
| Parallel Operation | 1+1 system (redundant operation) | ||
| Measurements | Input/Output voltage and current | ||
| Protection | Fan failure, fuse, parallel fault, high ripple | ||
| Other | SPD, cabinet heater, lighting, service outlet | ||
| STANDARDS | |||
| EN62040-1 | UPS safety standards | ||
| EN62040-2 | EMC standards | ||
| ISO14001 – ISO9001 | Quality management | ||
No documents found for this product.