PLP / PLTM Series
PLP / PLTM Series
The PLP/PLTM Series Three Phase Tower UPS is a high-performance power protection solution developed for the uninterrupted and secure supply of critical loads. Thanks to its online double conversion technology, it completely isolates fluctuations from the grid, providing clean and stable power. With a 0.9 output power factor and high efficiency of up to 95.5% in inverter mode, it offers a powerful yet energy-saving structure. Smart battery management and adjustable battery capacity allow it to easily adapt to different needs. With its compact design, advanced environmental durability, and parallel operation support (up to 4 devices), it provides a reliable solution for a wide range of applications, from data centers to telecom infrastructures, industrial production to building management systems.
- Features
- Parameters
- Documents
- Get a Quote
- Online Double Conversion UPS Technology
- 0.9 Output Power Factor
- High Efficiency up to 95.5% in Inverter Mode
- Smart Battery Management System
- Adjustable Battery Capacity
- Advanced Environmental Durability Design
- Compact and Space-Saving Structure
- Parallel Operation Support for up to 4 Devices
- Wide Input Voltage Range (138V – 485V AC)
- High Input Power Factor (≥0.99)
- Low Harmonic Distortion (THD)
- ±1% Precise Output Voltage Regulation
- User-Friendly Interface with Touch Screen
- Advanced Protection Features (short circuit, overload, over temperature, low battery, etc.)
- Wide Communication Options such as USB, RS485, SNMP, Parallel Card
| KEY FEATURES | |
|---|---|
| Phase | Three Phase Input / Three Phase Output |
| Type | Tower |
| Capacity | 10kVA 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA 100kVA 120kVA 160kVA 180kVA 200kVA |
| PARAMETERS | |
| Input Voltage | 380 / 400 / 415VAC |
| Input Voltage Range | 138~485VAC |
| Input Power Factor | ≥0.99 |
| Input Frequency | 40Hz – 70Hz |
| THD | Non-Linear Load: ≤3% |
| Bypass Voltage Range | Max. voltage: 220VAC: +25% (optional +10%, +15%, +20%) 230VAC: +20% (optional +10%, +15%) 240VAC: +15% (optional +10%)Min. voltage: -45% (optional -10%, -20%, -30%) |
| Frequency Range | ±10% |
| Generator Compatibility | Supported |
| Output Voltage | 380 / 400 / 415VAC |
| Voltage Regulation | ±1% |
| Output Frequency | Mains Mode: ±1% / ±2% / ±4% / ±5% ±10% optionalBattery Mode: (50/60 ±0.1%)Hz |
| Output Power Factor | 0.9 |
| Efficiency | 95.5% |
| Crest Factor | 3:1 |
| THD | Linear Load: ≤2% Non-Linear Load: ≤4% |
| Overload | ≤110%: 60 min ≤125%: 10 min ≤150%: 1 min >>150%: transfers to bypass |
| Battery | Supports Internal and External battery depending on power |
| Display | Touch Screen |
| Protection | Short circuit, overload, over temperature, low battery, fan failure alarm |
| Communication | USB, CAN, RS485, FE, LBS, Parallel card, Relay card, SNMP card (optional) |
| ENVIRONMENT | |
| Noise (1m distance) | 55-70dB |
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C (without battery) |
| Humidity | 0% ~ 95% (non-condensing) |
| Altitude | <1500m |
| STANDARDS | |
| EN62040-1 | General and Safety Requirements for UPS |
| EN62040-2 | Electromagnetic Compatibility (EMC) Requirements for UPS |
No documents found for this product.