PLP / PLTM Series

The PLP/PLTM Series Three Phase Tower UPS is a high-performance power protection solution developed for the uninterrupted and secure supply of critical loads. Thanks to its online double conversion technology, it completely isolates fluctuations from the grid, providing clean and stable power. With a 0.9 output power factor and high efficiency of up to 95.5% in inverter mode, it offers a powerful yet energy-saving structure. Smart battery management and adjustable battery capacity allow it to easily adapt to different needs. With its compact design, advanced environmental durability, and parallel operation support (up to 4 devices), it provides a reliable solution for a wide range of applications, from data centers to telecom infrastructures, industrial production to building management systems.
  • Features
  • Parameters
  • Documents
  • Get a Quote
  • Online Double Conversion UPS Technology
  • 0.9 Output Power Factor
  • High Efficiency up to 95.5% in Inverter Mode
  • Smart Battery Management System
  • Adjustable Battery Capacity
  • Advanced Environmental Durability Design
  • Compact and Space-Saving Structure
  • Parallel Operation Support for up to 4 Devices
  • Wide Input Voltage Range (138V – 485V AC)
  • High Input Power Factor (≥0.99)
  • Low Harmonic Distortion (THD)
  • ±1% Precise Output Voltage Regulation
  • User-Friendly Interface with Touch Screen
  • Advanced Protection Features (short circuit, overload, over temperature, low battery, etc.)
  • Wide Communication Options such as USB, RS485, SNMP, Parallel Card
KEY FEATURES
Phase Three Phase Input / Three Phase Output
Type Tower
Capacity 10kVA 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA 100kVA 120kVA 160kVA 180kVA 200kVA
PARAMETERS
Input Voltage 380 / 400 / 415VAC
Input Voltage Range 138~485VAC
Input Power Factor ≥0.99
Input Frequency 40Hz – 70Hz
THD Non-Linear Load: ≤3%
Bypass Voltage Range Max. voltage:
220VAC: +25% (optional +10%, +15%, +20%)
230VAC: +20% (optional +10%, +15%)
240VAC: +15% (optional +10%)Min. voltage:
-45% (optional -10%, -20%, -30%)
Frequency Range ±10%
Generator Compatibility Supported
Output Voltage 380 / 400 / 415VAC
Voltage Regulation ±1%
Output Frequency Mains Mode:
±1% / ±2% / ±4% / ±5% ±10% optionalBattery Mode:
(50/60 ±0.1%)Hz
Output Power Factor 0.9
Efficiency 95.5%
Crest Factor 3:1
THD Linear Load: ≤2%
Non-Linear Load: ≤4%
Overload ≤110%: 60 min
≤125%: 10 min
≤150%: 1 min
>>150%: transfers to bypass
Battery Supports Internal and External battery depending on power
Display Touch Screen
Protection Short circuit, overload, over temperature, low battery, fan failure alarm
Communication USB, CAN, RS485, FE, LBS, Parallel card, Relay card, SNMP card (optional)
ENVIRONMENT
Noise (1m distance) 55-70dB
Operating Temperature 0°C ~ 40°C
Storage Temperature -25°C ~ 55°C (without battery)
Humidity 0% ~ 95% (non-condensing)
Altitude <1500m
STANDARDS
EN62040-1 General and Safety Requirements for UPS
EN62040-2 Electromagnetic Compatibility (EMC) Requirements for UPS