PLI Series

Electric motors constitute a significant portion of the electrical load in industrial facilities. Should electric motors fail, production in factories can cease. Furthermore, critical electrical loads such as computer systems, medical devices, communication systems, control and alarm systems, or lighting systems must be protected and supplied with backup power. These critical loads should remain unaffected by power outages. Additionally, conditions such as high or low voltage, sudden voltage surges, or frequency fluctuations can occur in the electrical grid. In such scenarios, it is essential to both protect electrical systems and ensure backup power. Our PL Series devices are designed for this purpose.
  • Features
  • Parameters
  • Documents
  • Get a Quote
  • Pure sine wave output
  • 50 – 400 Hz operating range
  • Output isolation transformer
  • IPM or IGBT technology
  • Fast processing structure with DSP control
  • High overload capacity
  • Protection class from IP20 to IP55
  • Audible and LED alarm system
  • Modbus protocol compatible communication
  • TMS protection on all terminals
  • Automatic startup and recovery after fault
  • Self-diagnosis and log recording system
  • Smart charging feature and built-in battery monitoring
  • Modular card structure for easy maintenance and repair
KEY FEATURES
Model PLI1100 PLI3100 PLI3300
Input Phase Single Phase Three Phase Three Phase
Output Phase Single Phase Single Phase Three Phase
Nominal Power Up to 40kVA Up to 200kVA Up to 1000kVA
INPUT PARAMETERS
Mains & Bypass Voltage 110VAC / 115VAC / 120VAC
220VAC / 230VAC / 240VAC (Optional)
Voltage Range ±10% (±15% / ±20% optional)
Connection 2W (P+N) 3W (3P) / 4W (3P+N)
Frequency 50Hz, 60Hz or 400Hz (±10%)
Rectifier Type Full Bridge 6-Pulse / 12-Pulse
OUTPUT PARAMETERS
Output Voltage 110VAC / 115VAC / 120VAC
220VAC / 230VAC / 240VAC
190VAC / 200VAC / 210VAC
380VAC / 400VAC / 415VAC
440VAC / 460VAC / 600VAC
Frequency 50Hz, 60Hz or 400Hz (±15%)
Power Factor 0.8 (Optional 1)
THDu 2% (linear load)
Crest Factor 3:1
Recovery Time 25ms (±1% tolerance)
Overload 110%: Continuous
110-125%: 10 min
125-150%: 1 min
Isolation Galvanic isolation transformer
BATTERY PARAMETERS
Battery Type VRLA / OPzV / OPzS / Ni-Cd
Battery Voltage 110VDC / 220VDC (Optional) – 384VDC (Standard)
Charge Voltage VRLA / OPzV / OPzS: 2.23VDC – 2.35VDC (Float), 2.40VDC (Boost)
Ni-Cd: 1.42VDC – 1.7VDC
Charge Current VRLA: 10-15% capacity
Ni-Cd: 20% capacity
Boost Duration 0 – 20 hours (adjustable)
PHYSICAL CHARACTERISTICS
Cabinet Type Tower type (Optional)
Color RAL7032, RAL7035
Protection Class IP20 (Optional: IP21 – IP55)
Cooling Fan-cooled (Optional: natural / water / smart fan)
Cable Entry Bottom (Optional: top, rear, side)
ENVIRONMENTAL CONDITIONS
Storage -25°C / +70°C
Operating -10°C / +50°C
Humidity 0% – 95%
Altitude 1000m (1% derating thereafter)
Noise 55dB – 85dB
COMMUNICATION
Standard ModBus RTU (RS232) + optional RS485 / TCP-IP / SNMP
Parallel Passive: unlimited (Optional active: 4 devices)
HMI LED/LCD (Optional: touchscreen)
Languages TR, EN, DE, NL, PT, ES, RU
PROTECTIONS
Battery Temperature compensation, LVD, current limiting
Input/Output MCB / MCCB
STANDARDS
EN62040-1 UPS safety
EN62040-2 EMC
ISO14001 – ISO9001 Quality

No documents found for this product.